Mytech OMNI US1000 OCCUPANCY SENSOR ULTRASONIC CEILING MOUNT NEW!!
$ 22.87$ 13.72
Availability: 14 in stock
Description
Size Guide
Description
Dual Technology Sensor
The most advanced
sensor available.
Combines dual
technology with alldigital
architecture.
Eliminates false
triggering. The result is
a trouble-free, “install
and forget” solution
for lighting control.
The OMNI-DT Series Occupancy Sensor
Composite Infrared & Ultrasonic
Simple, Fast Installation
Self Adjusting (Adaptive)
All-digital, Complete Reliability
Optional Photocell & Extra Contacts
Ceiling Mount
GENERAL OPERATION
Occupancy sensors have two tasks: keeping the
lights on while the room is occupied and, conversely
keeping the lights off when unoccupied.
Ultrasonic (doppler shift) motion detection gives
maximum sensitivity yet can be vulnerable to false
triggering from air conditioning currents, corridor
activity and movement of inanimate objects. Infrared
motion detection gives immunity to false triggering,
but lacks sensitivity at greater distances.
COMPOSITE DUAL TECH SENSING
Using infrared sensing (high error immunity) with ultrasonic
(high sensitivity) provides good performance. Conventional
dual tech sensors use a simple formula for operation:
BOTH for ON, EITHER for KEEP ON. This method
requires that both sensors receive fixed-strength signals
for ON or a single fixed-level signal for KEEP ON.
The OMNI uses a more sophisticated method called a
composite singal where the signal strengths are added together
to form a composite sum. The advantage of this
method is that a week IR signal plus a strong US signal will
turn the lights on because the sum is enough. The installer
need not worry that the signal level be balanced for reliable
lights on.
ADAPTIVE FUNCTIONS
The OMNI constantly analyzes and adapts to changing
conditions:
When unoccupied, lights stay off while air conditioning system
cycles on and off, and cleaning crews occupy corridors.
Note: two major errors in Circadian mode (such as a false-off) will
cause Learning Phase to restart.
Installation
Learning
Post
Learning -
Occupancy
Periods
(Circadian)
60 min.
Four
weeks
After
four
weeks
Timer automatically resets from
Test (8 sec.) to 8 minutes.
1. Response to Error Conditions:
(false-ons, false-offs)
2. Air current adaptation
3. Timer optimization
Adjustments Made:
Ultrasonic sensitivity
Infrared sensitivity
Timer
Air current threshold
1. 24 hour occupancy periods
learned (circadian)
2. Weekly occupancy periods
learned
Adjustments Made:
a. Generally occupied periods:
Threshold=High Sensitivity
mode
b. Generally unoccupied periods:
Threshold=Miser mode